Boiler Not Working in Hamilton? What to Check
A few safe checks, in the right order, tell you whether it is a quick fix or a service call. Start with the safety notice, then find your symptom.
Gas smell or a carbon monoxide alarm? Do this first. For gas, leave right away and call from a safe place: the Enbridge Gas emergency line is 1-866-763-5427, or 911. Do not use switches, electronics or a phone inside, do not smoke and do not look for the leak. For a carbon monoxide alarm, go outside, call 911 and stay out until a professional says it is safe.
When a boiler stops heating, the cause is often one of a handful of things you can check yourself in a few minutes: power, the thermostat, the gas valve or the system pressure. If those are fine, the fault is usually a single part, such as a pump, a zone valve or an ignition part, and that needs a technician. Hamilton's winters are mild, with only about 3 days a year below -20 °C, so a boiler that quits here is more often worn out than overwhelmed by the cold.
Find Your Symptom
| What is happening | Most likely causes | Can you check it? |
|---|---|---|
| Nothing at all: no lights, no sound | Switch off, breaker tripped, control board | Switch and breaker, yes |
| Tries to light, then stops | Ignition part, flame sensor, gas valve closed | Gas valve position, yes |
| Boiler hot, whole house cold | Circulator pump, air in the system | Bleeding, yes; the pump, no |
| One area cold, the rest warm | Zone valve, its motor head, or that zone's thermostat | The thermostat, yes |
| Radiators warm at the bottom, cool at the top | Trapped air | Yes |
| Pressure keeps dropping | A leak, or a failed expansion tank | Look for water, yes |
| Relief valve dripping | Pressure too high, often the expansion tank | No |
| Banging, kettling or gurgling | Scale or sludge, air, weak circulation | Bleeding helps with air |
| Fault code on the display | Depends on the code | Note it for the technician |
No Heat at All: First Checks
- Power. The service switch near the boiler should be on, and the breaker should not be tripped. If the breaker trips again straight after a reset, leave it off and call.
- Thermostat. Set to heat, a few degrees above room temperature, with fresh batteries if it uses them.
- Gas. The gas valve to the boiler should be open. If the stove or water heater has also stopped, it may be a supply problem: follow the safety notice above.
- Pressure. Compare the gauge with the range in the manual. Many boilers will not fire if pressure is too low.
- The outdoor vent. On a high-efficiency boiler, check after a snowfall that the vent and air intake on the outside wall are not buried or blocked.
- The display. Write down any fault code along with the model and serial number from the rating plate.
Cold Radiators
If radiators are cool at the top, bleed them with a radiator key until water comes out, then check that the pressure on the gauge is still in range. If a whole zone stays cold, check its thermostat first; if that is calling for heat, the zone valve or its motor is the likely fault. If every radiator is cold but the boiler is hot, the pump is the usual suspect.
Pressure That Will Not Hold
A sealed hot water system should hold its pressure. If the gauge keeps falling, water is leaving the system: look around the pump, valves, radiator connections and the pipe from the relief valve. If it keeps rising, or the relief valve keeps dripping, the expansion tank has probably failed. Topping up repeatedly hides the problem and brings fresh, mineral-bearing water into the system each time; Hamilton's water is medium hard, about 120 mg/L.
Water on the Floor
Trace the water to its source. A dripping fitting or valve is usually a modest repair. Water coming from the boiler body or heat exchanger usually means the boiler is near the end of its life; turn it off and call. If the leak is near the burner or the electrical controls, switch the boiler off at the service switch before you look closer.
Noisy Pipes and Boiler
Gurgling is mostly air, and bleeding usually quiets it. A rumble or knock from the boiler itself, a sound like a kettle, often means scale or sludge on the heat exchanger or poor circulation. In older Hamilton houses, about a third of which were built by 1960, sludge in old piping is a common contributor. Noise that grows, or comes with pressure problems, needs a technician.
When to Call
- The boiler locks out again after one reset.
- Pressure keeps falling, or the relief valve keeps dripping.
- Water is coming from the boiler itself.
- A zone stays cold after bleeding and a thermostat check.
- You smell gas or a carbon monoxide alarm has gone off.
Gas work on a boiler must be done by a TSSA-registered contractor whose technicians hold TSSA certificates. The diagnosis visit runs about $99 plus HST at one Ontario service company, $129 plus HST on weekends and holidays. Parts and faults are covered in boiler repair in Hamilton and prices in the boiler repair cost guide. To avoid the next breakdown, see boiler service and maintenance.
Directory · 3 companies
Top-rated boiler companies in Hamilton
Independently selected on Google rating, review volume and years in Hamilton. Every company here is rated 4.7 or higher. Tap one to open its Google listing, with phone number, hours and recent reviews.
-
View on Google
HAMCO Heating and Cooling
Family-owned Hamilton company since 1946, on Queen Street North. Furnaces, air conditioning, heat pumps, boilers, water heaters and HRVs.
-
View on Google
Shipton's Heating & Cooling
Family-owned company in Stoney Creek, first opened in 1924. Furnaces, air conditioning, heat pumps, boilers and water heaters, including tankless.
-
View on Google
Aire One West Heating & Cooling
Hamilton heating and cooling company on Upper James Street. Furnaces, air conditioning, heat pumps, boilers and water heaters.
Frequently Asked Questions
Most often air in the system, a pump that has stopped or a zone valve stuck closed. Bleed the radiators first; the pump and valve need a technician.
There is a leak somewhere in the system, or the expansion tank has failed. Find the cause rather than topping up again and again.
Once, following the manual. If it locks out again, call a technician and give them the fault code.
A slow drip from a fitting is not an emergency, but water near the burner or electrical parts is a reason to switch the boiler off. A gas smell is an emergency: leave and call from outside.
One Ontario service company lists $99 plus HST for the diagnosis, or $129 plus HST on weekends and holidays, with the repair extra.