Boiler Not Working? What to Check First
Most boiler problems come down to a thermostat or power issue, trapped air, low pressure, or one failed part; here is what you can safely check yourself.
The house is cold and the radiators are lukewarm or stone cold. Before you book a visit, a few checks take five minutes and sometimes fix it. This page walks through the common boiler problems, then says where to stop and call someone.
Gas smell: If you smell gas, leave right away, leave the door open behind you, and from a safe place call 911 or Manitoba Hydro at 1-888-624-9376.
Quick Diagnosis: What You Are Seeing
| What you see | Common causes | Safe things to try |
|---|---|---|
| No heat at all | Thermostat, power or breaker, boiler locked out, failed igniter or control | Check the thermostat, the boiler switch and the breaker |
| Radiators cold, boiler running | Failed circulator pump, stuck zone valve, air in the system | Note which zones are cold; bleed cold-topped radiators |
| Radiator warm at the bottom, cold at the top | Trapped air | Bleed the radiator |
| Pressure dropping | Leak, failed expansion tank, relief valve discharging | Read the gauge; look for water around the boiler and valves |
| Water around the boiler | Leaking relief valve, fitting or valve; a leak from the boiler itself | Switch it off; see below |
| Banging, gurgling or whistling | Air in the pipes, a failing circulator, mineral build-up | Bleed radiators; otherwise call |
Boiler Not Working: No Heat at All
- Thermostat. Confirm it is set to heat and above the room temperature. On a multi-zone system, check each zone's thermostat.
- Power. Check the boiler's switch and the breaker. If the breaker has tripped, reset it once. If it trips again, stop.
- Pressure gauge. Compare the reading with the range in the boiler's manual. A boiler with very low pressure may shut itself down.
- Error code or lockout light. Many boilers show a code. Write it down and have it ready when you call.
If those are fine and the boiler will not fire, the likely culprit is an igniter, flame sensor or control. That is typically a $175–$550 repair, parts and labour included. For other repairs, see what boiler repairs cost in Winnipeg.
Boiler Is Running but the Radiators Are Cold
If the boiler fires but the heat does not reach the rooms, the pump that moves water through the pipes may have failed, or a zone valve may be stuck. If only one zone is cold, suspect the zone valve; if every zone is cold, suspect the circulator. A zone valve is typically $200–$550 and a circulator $250–$900 installed.
Boiler Losing Pressure
A boiler that keeps dropping below its normal pressure has lost water somewhere. The usual causes are a leak at a valve or fitting, a failed expansion tank, or a relief valve that is letting water out. Look around the boiler and under valves and radiators for water or rust stains. Refilling is a job for a technician unless the boiler's manual describes it, and if the pressure keeps falling there is a leak to find. Pressure that climbs too high and makes the relief valve drip points to the expansion tank. A relief valve is typically $150–$350 and an expansion tank $200–$600.
Boiler Leaking
Switch the boiler off at its switch, put a bucket or towels under the drip, and close the water feed valve to the boiler if you can find it. Then work out where the water is coming from:
- From the relief valve or its discharge pipe: usually pressure or an expansion tank problem.
- From a valve, fitting or pipe: a repair, typically $175–$600.
- From the boiler itself: a leaking heat exchanger or cracked section is usually a replacement. See boiler replacement cost in Winnipeg.
Boiler Banging, Gurgling or Whistling
Banging, gurgling or a whistle from the boiler or pipes usually points to air in the system, a circulator on its way out, or mineral build-up inside the boiler. Bleeding the radiators (below) clears trapped air. If the noise continues after bleeding, or the boiler is old, have it looked at.
Radiators Cold at the Top: How to Bleed Them
Air trapped in a radiator leaves the top cold while the bottom is warm. Bleeding a radiator with a radiator key is a safe job for a homeowner.
- Turn the heat off and let the radiators cool, since the water can be hot enough to scald.
- Hold a cloth under the bleed valve at the top corner of the radiator.
- Open the valve a quarter turn with the key until the hissing stops and water appears, then close it.
- Check the boiler's pressure gauge. It should be back in the range shown in the manual; if it has dropped, call a technician.
A technician visit to bleed radiators is typically $100–$200.
When to Call Someone
- The breaker trips again after you reset it.
- The boiler shows a code or lockout and will not restart.
- Pressure keeps falling, or the relief valve keeps dripping.
- Water is coming from the boiler itself.
- Bleeding does not fix cold radiators, or the whole house is cold.
- You smell gas (see the alert at the top of this page).
See boiler repair in Winnipeg to find who to call. If the boiler is old and the problems are piling up, compare with the boiler and radiator homes guide. For yearly care that prevents many of these, see boiler service and maintenance.
Directory · 1 company
Top-rated boiler companies in Winnipeg
Independently selected on Google rating, review volume and years in Winnipeg. Every company here is rated 4.7 or higher. Tap one to open its Google listing, with phone number, hours and recent reviews.
-
View on Google
Shorty's Plumbing & Heating
Family-owned since 1983. Heating, cooling, boilers, hot water tanks and plumbing, so one call covers both.
If problems keep coming back, see signs your boiler needs replacing in Winnipeg.
Frequently Asked Questions
Start with the thermostat, the boiler's switch and the breaker. Then check the pressure gauge. If those are fine, a failed igniter, control, circulator pump or zone valve is likely.
Usually a thermostat or power problem, low pressure, or a part that has failed to fire the boiler or move the water. If the boiler runs but the radiators stay cold, the pump or a zone valve is the usual cause.
The system is losing water: a leaking valve or fitting, a failed expansion tank, or a relief valve that keeps opening. Look for water and rust stains, then have a technician find the leak.
From a valve or fitting, it is typically a $175–$600 repair. A dripping relief valve points to pressure or the expansion tank. A leak from the boiler's own heat exchanger usually means replacement.
Trapped air. Bleed the radiator with a radiator key, then check the boiler's pressure is back in its normal range.
Air in the pipes, a failing circulator or mineral build-up inside the boiler. Bleed the radiators first; if the noise stays, call a technician.
Your domestic hot water comes from a different part of the system: the combi boiler's hot water side, or a separate water heater or tank. See water heater repair in Winnipeg if you have a separate tank.
You can check the thermostat, power and pressure gauge, and bleed radiators. Anything involving gas, the burner, valves or pumps is for a technician.