Troubleshooting

Heat Pump Not Working in Winnipeg? Here's What to Check First

Not heating, blowing cold air or covered in ice: match the symptom to the cause, run the checks that cost nothing, and know when it is a repair call.

SD Editorial
ServiceDispatch Editorial Team ServiceDispatch.ca
Written for Winnipeg, MB

When a heat pump stops heating in a Winnipeg winter, the cause is often something you can check in ten minutes: a thermostat setting, a clogged filter, or snow packed around the outdoor unit. Some of what looks like a fault, such as steam from the unit or a spell of cooler air, is the heat pump defrosting itself and is normal. This page covers a ducted heat pump or a ductless mini split that is running badly or not at all.

Find Your Symptom

What you noticeMost likely causeWho fixes it
Heat pump not heating, outdoor unit silentThermostat setting, tripped breaker, failed capacitor or contactorYou to start with, then a technician
Heat pump blowing cold airDefrost cycle, wrong thermostat mode, low refrigerant or a stuck reversing valveWait out defrost; otherwise a technician
Outdoor unit covered in ice or frostNormal frost between defrosts, snow blocking airflow, or a defrost faultYou can clear snow; a technician for a fault
Weak airflow from ventsDirty filter or blocked registersYou
Steam and a stopped outdoor fanDefrost modeNobody; this is normal
Short cycling: starts and stops every few minutesDirty coil, low refrigerant, sensor or control faultTechnician
Grinding, banging or squealingFan motor, loose fan blade or compressor troubleTechnician; switch it off first

What Is Normal in a Winnipeg Winter?

Near or below freezing, frost forms on the outdoor coil while the heat pump heats. Natural Resources Canada says the unit then runs a defrost cycle: it briefly reverses, melts the frost, and shuts off the outdoor fan while it does. Cycles can start every 30, 60 or 90 minutes on timer-based models, or only when needed on demand-defrost models. During defrost you may see vapour rising from the outdoor unit and hear the fan stop and a whoosh as the valve switches. The air from the vents also turns cooler for a few minutes, because the system is not heating while it defrosts.

A thin layer of frost that melts away is fine. A thick shell of ice that is still there after several defrost cycles is not.

Heat Pump Not Heating: Checks to Run First

  1. Thermostat. Confirm it is set to Heat, the set point is above the room temperature, and the display is on (replace the batteries if it has them).
  2. Breaker and switch. Check the breakers for the indoor and outdoor units and the disconnect box beside the outdoor unit.
  3. Filter and registers. A clogged filter chokes airflow. Natural Resources Canada says to change or clean it every three months; in winter, check it monthly. Make sure registers are open and not covered by furniture or rugs.
  4. Outdoor unit. Clear snow, ice and leaves from around it. Snow piled against the unit starves it of air. Keep at least 2 to 3 feet clear on all sides, per Carrier Canada.
  5. Wait through a defrost. If the unit is steaming, give it about 10 minutes before deciding anything is wrong.

If it still will not heat, switch the system off at the thermostat and breaker for 30 minutes, then restart it once. If you have a dual-fuel system with a gas furnace, the furnace can keep the house warm while you sort this out.

Heat Pump Frozen or Iced Up

If the outdoor coil is buried in ice, turn the system off at the thermostat and breaker, wait at least 30 minutes, then pour hot water over the ice. Do not chip at it with a tool, which can puncture the coil, and keep water away from electrical parts. Restore power, wait another 30 minutes and restart. This is the process Save Energy NB, a Canadian utility efficiency program, recommends.

If ice returns within a day or two, something is wrong: a failed defrost control board or sensor, low refrigerant, a stuck reversing valve or a blocked drain. A technician needs to find which. A defrost control board repair is typically $350–$600 in Winnipeg.

Heat Pump Blowing Cold Air

Work through these in order:

Emergency Heat and Backup Heat

Winnipeg's cold snaps reach -40°C, well below what a heat pump can handle alone, so every system has backup heat: electric coils in the air handler, or the gas furnace in a dual-fuel setup. Natural Resources Canada notes that backup heat may also run during defrost. If your thermostat has an Emergency or Aux Heat setting, it turns the heat pump off and runs only the backup. Use it as a stopgap while you wait for a repair, not as a normal setting; electric backup costs more to run than the heat pump.

If the backup heat runs a lot more than it used to, or the house will not warm up even with it, the heat pump is not working properly. Call for service.

Mini Split Not Working

A mini split not working has the same outdoor-unit causes as a ducted heat pump: snow, ice, a tripped breaker, a failed capacitor or a fault in the defrost controls. On the indoor head, start with the remote (batteries, mode set to Heat) and the filter, which Mitsubishi Electric Canada says to clean as often as usage requires. A blinking light or an error code on the head is worth writing down for the technician. A blocked condensate drain or a failed indoor fan motor or control board is a technician's job. See the Winnipeg mini split guide for how these systems work.

When to Call a Technician

Call if the heat pump will not run after the checks above, ice keeps coming back, the compressor or fan makes grinding or banging noises, the unit short cycles, or you smell burning. A heat pump that quits in a cold snap rarely does it at a convenient hour; after-hours calls add $75–$150. For companies that fix them, see heat pump repair in Winnipeg.

Typical 2026 Winnipeg repair prices: diagnostic fee $100–$180 · capacitor $150–$280 · contactor $150–$300 · defrost control board $350–$600 · reversing valve $600–$1,200 · compressor $900–$1,500 or more. The full table is in heat pump repair cost in Winnipeg.

If the unit is more than 10 to 12 years old and the repair is a big one, compare it with replacement: see heat pump repair or replace, signs your heat pump needs replacing and heat pump installation cost in Winnipeg. To prevent the next breakdown, book a heat pump tune-up before winter.

Directory · 4 companies

Top-rated heat pump companies in Winnipeg

Independently selected on Google rating, review volume and years in Winnipeg. Every company here is rated 4.7 or higher. Tap one to open its Google listing, with phone number, hours and recent reviews.

  1. Tradesman Mechanical Services

    4.9 · 570+ Google reviews

    Winnipeg mechanical contractor for furnaces, air conditioning, heat pumps, water heaters, refrigeration and electrical.

    View on Google
  2. Abundant Air

    4.9 · 470+ Google reviews

    Winnipeg heating and air conditioning company. Furnaces, air conditioning and heat pumps.

    View on Google
  3. Provincial Heating & Cooling

    4.8 · 400+ Google reviews

    Winnipeg heating and cooling company and Carrier dealer. Furnaces, air conditioning, heat pumps and water heaters.

    View on Google
  4. Shorty's Plumbing & Heating

    4.8 · 610+ Google reviews

    Family-owned since 1983. Heating, cooling, boilers, hot water tanks and plumbing, so one call covers both.

    View on Google

Frequently Asked Questions

Check the thermostat is on Heat, the breakers are on, the filter is clean and the outdoor unit is clear of snow and ice. If all that is fine and the outdoor unit is silent, a failed capacitor or contactor is likely and needs a technician.

Most often it is in defrost, which lasts a few minutes, or the thermostat is on Auto or Cool. If the air stays cold, the cause is low refrigerant, a stuck reversing valve or a failed compressor.

Yes. Vapour from the outdoor unit while the fan is stopped is the defrost cycle melting frost. Worry only if it steams continuously, or the ice stays thick after defrost.

Thin frost is normal. Thick ice means snow is blocking airflow, or the defrost board or sensor, the refrigerant charge or the reversing valve has failed. Thaw it with hot water after shutting the power off, and call if it returns.

A thermostat setting that shuts off the heat pump and runs only the backup heat, either electric coils or the furnace. Use it temporarily if the heat pump has failed. It costs more to run.

A cold-climate model can, but output falls as the temperature drops. Natural Resources Canada puts the minimum operating temperature of newer air-source models between -15°C and -25°C, and describes cold-climate units as working to about -30°C. In a Winnipeg cold snap the backup heat carries the house.

Short cycling usually comes from a clogged filter, a dirty coil, low refrigerant or a faulty sensor. Replace the filter and clear the outdoor unit; if it continues, call a technician.

Most fixes cost $150–$400, such as a capacitor or contactor. A reversing valve is $600–$1,200 and a compressor $900–$1,500 or more, plus a $100–$180 diagnostic fee.