Troubleshooting

Heat Pump Not Working in Calgary? Start With These Checks

No heat, cool air or ice after a chinook? Match the symptom to a cause, try the free fixes, and see when to call.

SD Editorial
ServiceDispatch Editorial Team ServiceDispatch.ca
Written for Calgary, AB

Much of what worries Calgary owners about a heat pump is normal. After a chinook, meltwater drips onto the outdoor unit and refreezes. Damp air near zero frosts the coil. The unit then runs defrost more often. Vapour rises outside and the indoor air runs cooler for a few minutes. Real faults look different, and the table below separates the two. Ducted systems and mini splits are covered together.

Symptoms and Likely Causes

What you noticeProbable causeWhat to do
Nothing happens, outdoor fan silentWrong thermostat mode, tripped breaker, worn capacitor or contactorLook at the mode and the breakers, then book service
Vents blow coolDefrost under way, thermostat on Cool or Auto, low refrigerant, reversing valve stuckGive it ten minutes, then confirm the mode
Frost or ice on the outdoor cabinetOrdinary frost, meltwater refreezing, or a defrost faultRedirect run-off and clear the area; call if heavy ice remains
Little air from the registersClogged filter or closed registersA job for you
Vapour rising and the fan stoppedDefrost cycleLeave it alone, this is expected
Short runs that stop and restartDirty coil, low charge, bad sensor or controlTechnician
Grinding, banging or a high squealFan motor, a loose blade, or the compressorShut it off and call

Defrost After a Chinook

Natural Resources Canada explains that a heat pump melts coil frost by running in reverse for a short time, in cooling mode with the outdoor fan stopped, and that supplementary heat may be needed meanwhile. Some units defrost on a timer. Others wait until sensors detect frost, which the agency calls generally more efficient. Either way, expect vapour at the unit and slightly cooler indoor air for a spell.

A dusting of frost that goes away is routine. A heavy shell that outlasts several cycles, or returns every day, is a problem. If roof water is landing on the unit and freezing there, the fix is to redirect the water.

Free Checks Before You Call

  1. Thermostat. Mode on Heat, setpoint above the room reading, screen on.
  2. Breakers. Both breakers, plus the disconnect box mounted beside the outdoor unit.
  3. Filter and registers. Natural Resources Canada advises a fresh or cleaned filter every three months. Move furniture off any covered register.
  4. Outdoor unit. Remove snow, ice chunks and debris. Carrier Canada says to leave at least 2 to 3 feet of open space around it.
  5. Time. Vapour means defrost is running, so give it a few minutes.

No change? Turn the system off at both the thermostat and the breaker for thirty minutes, then restart once. A gas furnace used as backup can warm the house meanwhile. If you ever smell gas, get out of the building and phone ATCO Gas at 1-800-511-3447 or 911 from outside.

Covered in Ice

Shut the system off at the thermostat and the breaker, then let the ice thaw by itself. Chipping is a bad idea since a tool can puncture the coil, and water must stay clear of the electrical parts. If the ice is back inside two days, something deeper is wrong: a defrost board or sensor, low refrigerant, a reversing valve that sticks or a drain that is blocked. Only a technician can tell which.

Cool Air When You Want Heat

Emergency Heat and Backup

Calgary's heating design temperature is -30 °C and roughly 3 days a year dip below it, so every heat pump here needs backup. Natural Resources Canada describes two arrangements: electric elements that work together with the heat pump, and a furnace or boiler that takes over rather than working at the same time. The Emergency or Aux setting on a thermostat calls for the backup alone. Keep it to a short-term fix. When backup is running much more than before, or the house is cold even with it, arrange a visit.

Ductless Units

A mini split's outdoor section fails the way a ducted one does. Inside, start at the remote, with new batteries and Heat selected, then look at the filter and write down any flashing light or code. Blocked drain lines and dead indoor fans or boards call for a technician. More at mini splits in Calgary and the Calgary heat pump guide.

Time to Call a Technician

Book service when the checks change nothing, ice comes back, you hear grinding or banging, the unit stops and starts every few minutes, or there is a burning smell. One Calgary company lists a $109.95 call-out and diagnosis in regular hours on its furnace and air conditioner pages, then $139.95 an hour. An Alberta service company lists a $125 plus GST diagnostic on weekdays, $185 plus GST on weekends and holidays.

For repair prices, see heat pump repair cost in Calgary.

An older unit facing a big bill should be compared with a new one at heat pump repair or replace. A yearly tune-up in the fall is the best defence against a repeat.

Directory · 3 companies

Top-rated heat pump companies in Calgary

Independently selected on Google rating, review volume and years in Calgary. Every company here is rated 4.7 or higher. Tap one to open its Google listing, with phone number, hours and recent reviews.

  1. Alberta Mountain Air Heating & Air Conditioning

    4.8 · 1,200+ Google reviews

    Family-owned Calgary company since 2004 and a Lennox dealer. Furnaces, air conditioning, heat pumps and hot water systems.

    View on Google
  2. AJ Furnace and Air Conditioning

    5.0 · 710+ Google reviews

    Calgary heating and cooling company on Highfield Crescent SE. Furnaces, air conditioning and heat pumps.

    View on Google
  3. Calgary Heating Services

    4.9 · 220+ Google reviews

    Calgary company on 11 Street NE. Furnaces, air conditioning, heat pumps, water heaters, HRVs, plumbing and electrical.

    View on Google

Frequently Asked Questions

Look first at the mode, breakers, filter and what is piled against the outdoor unit. If the unit stays silent after that, suspect a capacitor or contactor.

Usually defrost, or a thermostat left on Auto or Cool. If the air stays cool, think low refrigerant, a reversing valve or the compressor.

During defrost, yes. Constant steam, or ice that stays heavy afterward, calls for a technician.

A thin frost is normal. Heavy ice suggests restricted airflow, roof run-off refreezing on the cabinet, or a faulty defrost control, charge or reversing valve.

It runs the backup only, whether electric elements or the furnace. Use it for a short time.

Natural Resources Canada says newer air-source models run down to somewhere between -15 °C and -25 °C. The backup covers anything colder.

Commonly a clogged filter, dirty coil, low refrigerant or sensor fault. Clean the filter and clear the unit, then call if it persists.

One Calgary company lists a $109.95 call-out and diagnosis in regular hours, then $139.95 an hour. Repairs are extra.