Troubleshooting

HRV Not Working in Calgary? What to Check First

Weak airflow, fogged glass, ice on the core or hood after a chinook, or a noisy unit? Match the symptom and try the free fixes. Then see when to call a technician.

SD Editorial
ServiceDispatch Editorial Team ServiceDispatch.ca
Written for Calgary, AB

Many HRV complaints in Calgary are really timing problems. Winters swing fast, so a humidity setting left over from a cold snap can end up wrong. Hoods iced by a freeze, thawed by a chinook and frozen over again cause trouble too. So does a filter nobody has looked at since autumn. These checks are quick. A core that keeps icing, a tripping breaker or lopsided airflow needs a technician. This page covers an HRV or ERV that will not run, moves little air, ices up or leaves water on the glass. Unplug or disconnect the unit before opening it.

Smell gas, or a carbon monoxide alarm sounding? Stop here. For gas, leave the building immediately without touching lights, switches, phones or appliances, and call ATCO Gas at 1-800-511-3447 or 911 from outside. Do not light anything or smoke. If a carbon monoxide alarm sounds, get everyone outdoors and call 911. Natural Resources Canada warns that an HRV is no substitute for fixing an appliance whose combustion by-products are spilling into the house. Gas appliance repairs in Alberta belong to a Gasfitter Class B tradesperson.

Find Your Symptom

HRV Not Running: Checks to Run First

  1. Control. Confirm the wall control is on and in the right mode.
  2. Cord. See that the unit is plugged in and the cord is undamaged.
  3. Breaker. If a breaker has tripped or a fuse has blown, call a contractor. Natural Resources Canada says not to reset or replace either until the cause is found, since it is a fire and shock risk.

HRV Little or No Airflow

If air is still weak, call a contractor.

HRV Condensation on Windows

Wet glass tells you the indoor air holds more moisture than the outside temperature allows. Calgary's heating design temperature is -30°C, but a chinook can lift the outdoor temperature by 20°C within hours, so the right setting moves with it. Work through these in order:

  1. Lower the humidity control. A utility guide suggests 25% at -30°C and 35% at -18°C. The whole list is in the Calgary HRV guide.
  2. Cut moisture at its source with bathroom and kitchen fans, and less laundry hung indoors.
  3. Raise the HRV speed.
  4. Try the trash bag test further down.

If glass still streams, Natural Resources Canada says the minimum continuous ventilation rate may be too low for the house, which a contractor can fix.

HRV Frozen: What to Do

Most units defrost automatically once incoming air falls under about -5°C, with longer cycles as it gets colder. If ice still collects, Natural Resources Canada suggests:

  1. Opening the door and letting the ice melt. Some cores lift out for thawing in a sink.
  2. Washing or replacing filters.
  3. Testing the defrost mechanism or preheater if there is one, following the manual.
  4. Calling a contractor if the ice keeps returning. Airflows may need rebalancing, with more exhaust or less supply.

HRV Drain and Water Problems

Add two or three litres of warm water to the pan. If it pools, clear the drain with thin wire. The tubing needs a trap. Water or ice on a duct usually means the insulation jacket has a hole, which foil duct tape can fix when small. Insulation that is soaked or torn has to be replaced and resealed. A drain tube that froze during the cold and thawed in the warm wind can drip suddenly, so check it after a chinook.

HRV Noise and Vibration

Start by brushing or vacuuming dust off the fan blades with the power off. A unit that uses the furnace ducts can also carry the sound of the furnace blower when it runs at its higher heating speed. Grinding, rattling or a vibration that persists is a job for a technician.

HRV Air Too Dry

Winter air in a house can feel parched if the unit pulls out more moisture than you want, and chinook air is dry as well. Raise the humidity setting, run the HRV on low or let it cycle on and off. Make sure the exhaust is open and the core is not iced. An ERV keeps some moisture indoors, though Natural Resources Canada says it costs more than easier fixes.

How Do I Know if My HRV Is Working? The Trash Bag Test

Fasten a large trash bag to a coat hanger and hold it at the outdoor exhaust hood, noting how long it takes to inflate. Next hold the full bag at the intake hood and time how long it takes to empty. Times within a few seconds of each other suggest the flows are close to balanced. Natural Resources Canada calls it a rough check, not a measurement.

When to Call a Technician

Call if the breaker trips, the core keeps icing, airflow is weak after these steps, humidity will not settle or the unit is loud or locked on one speed. A technician can measure and rebalance airflow, test the defrost and inspect the wiring. HRV service is about $60 to $150 as an add-on, or $100 to $200 as its own visit: see HRV maintenance in Calgary. If the unit is beyond saving, HRV installation cost in Calgary prices a replacement. In Calgary the contractor, not the homeowner, pulls any mechanical permit.

Directory · 1 company

Calgary companies that list HRV work

These top-rated Calgary companies state HRV work on their own websites. Other listed companies may also do this work, so ask them. Tap one to open its Google listing, with phone number, hours and recent reviews.

  1. Calgary Heating Services

    4.9 · 220+ Google reviews

    Calgary company on 11 Street NE. Furnaces, air conditioning, heat pumps, water heaters, HRVs, plumbing and electrical.

    View on Google

Frequently Asked Questions

Make sure the control is on, the unit has power and the breaker has not tripped. Then wash the filters and clear the outdoor hoods. If it still will not start, or the breaker trips again, call a technician.

The indoor humidity target is too high for the outside temperature. Lower the control, speed the fan up and reduce moisture sources. If it persists, the unit may not be ventilating enough.

Melting frost can refreeze on hoods and cores when the cold returns, and defrost struggles when filters are dirty or the airflows are uneven. Let the ice melt, clean the filters and call a contractor if it comes back.

The usual culprits are a dirty filter, an iced hood, a shut damper or a frosted core. If airflow stays low, a duct may have separated or the unit may need service.

The fan may be running too fast or the humidity control set too low. Raise the setting and run the unit on low or intermittently.

HRV service is about $60 to $150 as an add-on to a furnace or duct cleaning, and about $100 to $200 as its own visit. A replacement HRV is about $1,500 to $2,800 installed on existing ducts.

See Top-Rated Companies