Troubleshooting

HRV Not Working in Saskatoon? Here's What to Check First

Weak airflow, fogged windows, ice on the core or a rattling unit: find your symptom, try the no-cost fixes, and learn which problems need a technician.

SD Editorial
ServiceDispatch Editorial Team ServiceDispatch.ca
Written for Saskatoon, SK

Frost clogs the outdoor hoods, filters load up with dust and the humidity dial ends up wrong for a cold snap, so most breakdowns start with one of those three. They are quick to rule out. A core that refreezes over and over, or a unit whose airflow is out of balance, is a technician's problem. Everything here applies to an HRV or an ERV that has quit, moves hardly any air, ices up or leaves water on the glass. Cut the power before opening the cabinet.

Find Your Symptom

What you noticeMost likely causeWho fixes it
HRV will not startWall control off, plug pulled, breaker trippedYou first; a technician if the breaker keeps tripping
Weak or no air at the grillesDirty filter, plugged hood, iced core, shut damper or a duct that has come apartYou
Fogged or wet windowsIndoor humidity set too high for the outdoor temperatureYou: turn the humidity control down
Ice on the core or inside the cabinetDefrost falling behind, a blocked filter, or supply and exhaust out of balanceYou to thaw it; a technician if it comes back
Dry air, static shocks, itchy throatFan speed too high or humidity control set too lowYou
Puddles under the unit or soaked duct insulationPlugged drain or a torn duct jacketYou, then a technician
Rattling, humming or shakingDust on the fan blades or a loud furnace blowerYou, then a technician
Only one speed works, or cold drafts from the ventsFaulty control, or the fresh air outlets sit in the wrong placeTechnician

HRV Not Running: Start Here

  1. Wall control. Confirm it is switched on and set to the mode you want.
  2. Plug and cord. The unit should be plugged in, with no cuts or crushed spots in the cord.
  3. Breaker. A tripped breaker or a blown fuse is a reason to phone a contractor. Natural Resources Canada warns against resetting it before the cause is found, since it may mean a shock or fire risk.

HRV Moving Little or No Air

Go down this list in order:

Airflow still poor after all that? Time for a contractor.

Condensation on the Windows

Wet glass tells you the house air carries more moisture than the cold outdoors can allow. Natural Resources Canada advises setting the dehumidistat to keep cold surfaces from sweating. Try these, one after another:

  1. Turn the humidity setting down. The lower the outdoor temperature, the lower the setting: the Saskatoon HRV winter settings table has the numbers.
  2. Stop moisture where it starts. Use the bathroom and kitchen fans, hang fewer clothes indoors and put away spare humidifiers.
  3. Switch the HRV to a faster speed.
  4. Confirm real airflow with the trash bag test further down.

Windows still fogging? Natural Resources Canada says the unit's minimum continuous ventilation rate could be set too low for the house, and a contractor can raise it. Dripping or frosted duct insulation suggests a damaged jacket, covered below.

A Frozen HRV

Most units start an automatic defrost once the air coming in drops below roughly -5°C, and the colder the day, the more time they spend defrosting. When the core freezes anyway, Natural Resources Canada suggests:

  1. Opening the door and letting the ice melt by itself. Some cores slide out so you can thaw them in the sink.
  2. Cleaning or replacing the filters.
  3. Checking the defrost mechanism, or the preheater if the model has one, against the manual.
  4. Calling a contractor if the ice returns. The balance may need adjusting, with more exhaust flow or less supply flow.

A Broan and vanEE manual tells owners to shut the unit off in the heaviest snowstorms. Positive pressure in the house, which forces damp indoor air out through the walls, can also frost the core and the door locks.

Drain and Water Problems

Water around the unit? Tip two or three litres of warm water into the pan. If it backs up, poke the drain clear with thin wire. The tubing needs a trap so that air is not drawn in through it. Drips or ice on a duct point to a hole in the insulation jacket. Seal small holes with foil duct tape, and replace insulation that is wet or damaged before resealing.

Noise and Vibration

Begin with the fan blades. With the power off, lightly brush or vacuum the dust away. When the HRV shares ductwork with the furnace, the blower at its high heating speed may be the real source of the noise. Natural Resources Canada notes that an efficient ECM motor can run quietly at low speed. A grinding sound, a rattle or a shake that will not go away calls for a technician.

Air Too Dry

Static shocks and a scratchy throat show that the HRV is pulling out more moisture than you want gone. Nudge the humidity setting up and run the unit at its lowest speed or on an intermittent cycle. Natural Resources Canada adds that an oversized HRV, or one running too fast, can dry the house out. Make sure nothing is blocking the exhaust and the core is not iced.

Is My HRV Working? The Trash Bag Test

Tape a big trash bag onto a wire coat hanger, hold it against the outdoor exhaust hood and note how long it takes to inflate. Next, hold the full bag against the intake hood and time its collapse. In a balanced system, the two times agree within a few seconds. Natural Resources Canada describes this as a rough check rather than a measurement.

If a furnace, water heater or fireplace is leaking fumes into the house, or a carbon monoxide alarm goes off, the HRV is not the answer. Natural Resources Canada says combustion by-products in the house mean the appliance or its venting needs repair right away, and a badly unbalanced HRV can draw those fumes back in.

When to Call a Technician

Phone one when the breaker trips, the core refreezes, airflow stays poor after the checks above, humidity problems will not settle, or the unit is noisy or stuck on a single speed. A technician can measure the airflow and rebalance it, test the defrost and inspect the wiring. A service runs about $60 to $150 as an add-on, or $100 to $200 as its own visit; HRV maintenance in Saskatoon explains what it covers. For a unit past saving, HRV installation and replacement cost in Saskatoon lists new-unit prices. Natural Resources Canada cautions against putting off a repair to save money, since a neglected system can lead to stale air and moisture trouble.

Directory · 2 companies

Saskatoon companies that list HRV work

These top-rated Saskatoon companies state HRV work on their own websites. Other listed companies may also do this work, so ask them. Tap one to open its Google listing, with phone number, hours and recent reviews.

  1. Centennial Plumbing, Heating & Electrical

    4.9 · 3,190+ Google reviews

    Saskatoon family business since 1967. Heating, cooling, boilers, water heaters, plumbing and electrical.

    View on Google
  2. Razor Heating & A/C

    5.0 · 750+ Google reviews

    Owner-led Saskatoon company since 2007. Furnaces, air conditioning, heat pumps, boilers and water heaters.

    View on Google

Frequently Asked Questions

Begin with the wall control, the plug and the breaker. Next, wash the filters and clear the hoods outside. An HRV that still refuses to start, or that trips the breaker again, needs a technician.

Indoor humidity is higher than the outdoor temperature allows. Turn the humidity control down, raise the fan speed and cut back on moisture sources. If the glass keeps fogging, the unit may be ventilating too little for your house.

In deep cold the defrost cycle can fall behind, usually because of dirty filters, a plugged hood or lopsided airflow. Let the ice melt with the door open, clean the filters, and bring in a contractor if the freeze-up returns.

A clogged filter, a hood packed with snow or frost, a shut damper or an iced core are the usual suspects. Work through those. Weak airflow after that points to a loose duct or a unit that needs service.

Dust on the fan blades, or the furnace blower running fast. Wipe the blades clean, and call a technician if the noise or shaking carries on.

The HRV may be running faster than the house needs, or the humidity control is set too low. Raise the setting and drop to low speed or an intermittent cycle. An ERV holds on to some moisture, and the City of Saskatoon says it is nearly always the better choice for Saskatchewan's cold, dry climate.

Only briefly. Thaw it, clean the filters and get the airflow balance checked. One Broan and vanEE manual recommends shutting the unit off during very heavy snowstorms.

HRV service is about $60 to $150 as an add-on to a furnace or duct cleaning, and about $100 to $200 as its own visit. Filters are about $20 to $60 for most units. A new unit installed on existing ducts typically runs about $1,500 to $2,800.

See Top-Rated Companies