Troubleshooting

Boiler Not Working? What to Check Before You Call

No heat, cold radiators, a dropping pressure gauge or water on the floor: most boiler faults have a short list of causes. Here is what to check, and when to call.

SD Editorial
ServiceDispatch Editorial Team ServiceDispatch.ca
Written for Edmonton, AB

Gas smell or carbon monoxide alarm: if you smell gas, leave the building and call ATCO Gas at 1-800-511-3447 or 911. If a carbon monoxide alarm sounds, get everyone outside and call 911.

About one in five households in the Edmonton area heats mainly with a boiler, and a failure in a cold snap is urgent. Some faults take minutes to check and occasionally clear themselves. Others need a technician. Work involving gas, or a leak from the boiler itself, is never a job for the homeowner.

No Heat From the Boiler

Go through the list in this order:

  1. Power. Confirm the boiler switch is on and the breaker has not tripped. A breaker that trips again after a single reset means stop and call.
  2. Thermostat. It should be set to heat, with a target above the room temperature, and have fresh batteries if it takes them.
  3. Gas. The shutoff at the boiler needs to be open. When other gas appliances are dead too, treat it as a gas problem and follow the message above.
  4. Display or lockout light. A lot of condensing boilers show a fault code. Note it, together with the model number from the rating plate.
  5. Pressure gauge. A boiler can shut itself down on low pressure. Normal range is in the manual.

If the boiler runs but the house stays cold, look further along the system: trapped air, a failed circulator pump or a stuck zone valve. A boiler that does nothing at all points to power, a control or an ignition part.

Cold or Half-Warm Radiators

Pressure That Keeps Falling

Dropping pressure means a leak somewhere, or an expansion tank that has failed. Check the pump, valves, radiator fittings and the pipe from the relief valve for drips. If the gauge falls again after you refill to the range in the manual, call someone. Edmonton water is hard, about 176 mg/L, so each top-up adds minerals to the system and repeat refills make things worse. Pressure that climbs too high usually traces to the expansion tank and often appears as a dripping relief valve.

Water Around the Boiler

The source could be a fitting or valve, which can be repaired, the relief valve, which often signals a pressure problem, or the boiler itself. Locate where it starts, turn the boiler off if water is flowing and call. A leaking heat exchanger or cast iron section generally means a new boiler, covered in boiler replacement in Edmonton.

Banging, Kettling and Gurgling

A bang, or a rumble like a kettle approaching the boil, may come from air, from scale or sludge on the heat exchanger, or from weak flow through a worn pump. Gurgling is normally air, and bleeding often cures it. If the noise grows, or appears with pressure loss or overheating, book a service call.

Time to Call

Alberta reserves gas work on boilers for the Class B gasfitter trade. See boiler repair in Edmonton and the boiler repair cost guide for prices. For the wider picture, see boilers in Edmonton.

Directory · 1 company

Top-rated boiler companies in Edmonton

Independently selected on Google rating, review volume and years in Edmonton. Every company here is rated 4.7 or higher. Tap one to open its Google listing, with phone number, hours and recent reviews.

  1. Weiss-Johnson Heating, AC & Plumbing

    4.8 · 1,940+ Google reviews

    Edmonton family business since 1977. Furnaces, air conditioning, heat pumps, boilers, water heaters, plumbing and HRVs.

    View on Google

Frequently Asked Questions

Typical causes are no power, a thermostat that is not calling for heat, a closed gas valve, low pressure, trapped air, a failed circulator pump or a stuck zone valve. The first four are yours to check.

Trapped air is the usual reason, followed by a failed pump or a zone valve stuck shut. Bleeding clears air.

Either water is leaking out or the expansion tank has failed. Refilling again and again only hides the cause.

A small drip at a fitting is a repair, yet water close to the controls is a reason to switch off and call. If you smell gas, leave the building and call ATCO Gas at 1-800-511-3447 or 911.

Air, scale or sludge on the heat exchanger, or poor flow. Bleed the radiators first and arrange a service if it carries on.

You can check the power, thermostat and gas shutoff, bleed radiators and read the gauge. Leave anything inside the boiler, anything with gas and any repeat fault to a licensed gas contractor.