Heat Pump Not Working in Edmonton? What to Check First
Not heating, blowing cool air or covered in ice: match what you see to a cause, try the free fixes, and know when to call.
On an Edmonton morning at -25 °C, a heat pump that seems dead often has a simple problem you can spot yourself: the wrong thermostat mode, a clogged filter or a drift against the outdoor unit. Other things that alarm people are normal. Steam off the unit and a short burst of cooler air are signs of a defrost cycle. Everything here applies to ducted systems and ductless mini splits.
Match the Symptom
| You see | Likely cause | Next step |
|---|---|---|
| No heat, outdoor fan not running | Thermostat mode, breaker, or a failed capacitor or contactor | Check settings and breakers, then call |
| Cool air from the vents | Defrost, thermostat on Cool or Auto, low refrigerant, stuck reversing valve | Wait a few minutes, then check the mode |
| Ice or frost on the outdoor unit | Normal frost, a drift against the unit, or a defrost fault | Clear snow; call if thick ice stays |
| Weak airflow | Dirty filter or closed registers | Fix it yourself |
| Vapour and a stopped fan | Defrost | Nothing, it is normal |
| Cycling on and off within minutes | Dirty coil, low refrigerant, sensor or control fault | Technician |
| Grinding, banging, squealing | Fan motor, loose blade or compressor | Switch off, then call |
What Defrost Looks Like
Below about freezing, the outdoor coil collects frost while the unit heats. Natural Resources Canada explains that the unit clears it by briefly running in cooling mode with the outdoor fan off, so the indoor air cools during that time. Defrost can start on a timer of 30, 60 or 90 minutes or only when sensors detect frost. Expect vapour at the outdoor unit while it happens.
A light dusting that melts is routine. A thick shell of ice that survives several cycles is a problem.
Free Checks When It Will Not Heat
- Thermostat. Set to Heat, target above the room temperature, display lit.
- Power. Look at both breakers and the disconnect box next to the outdoor unit.
- Filter and registers. Natural Resources Canada advises changing or cleaning the filter every three months. Uncover any register blocked by furniture.
- Outdoor unit. Dig it out of drifts. Carrier Canada says to keep 2 to 3 feet clear of debris and obstructions.
- Patience. If it is steaming, let the defrost finish.
Still nothing? Turn the system off at the thermostat and breaker for half an hour and try one restart. If a gas furnace is your backup, it can heat the house meanwhile. If you smell gas, leave the building and call ATCO Gas at 1-800-511-3447 or 911.
Frozen or Iced Over
Switch the system off at the thermostat and breaker and give the ice time to melt. Do not hack at it, since a tool can puncture the coil, and keep water off electrical parts. Ice that comes back within a day or two means a deeper fault: a defrost control or sensor, low refrigerant, a stuck reversing valve or a blocked drain. A technician has to pin down which.
Cool Air From a Heat Pump
- Defrost makes the air cooler for a few minutes.
- Thermostat mode. Cool, or Auto drifting into cooling, will do it. Choose Heat.
- Expectations. Heat pump air is warm, not furnace-hot. If the house holds its temperature, nothing is wrong.
- Outdoor temperature. Natural Resources Canada says newer air-source units can run down to somewhere between -15 °C and -25 °C, and below that a supplementary system must supply the heat. Edmonton sees about 791 hours a year under -15 °C.
- A fault. A silent outdoor unit suggests a capacitor or contactor. A running unit with cool air suggests low refrigerant, the compressor, or a reversing valve stuck on cooling.
Backup Heat and the Emergency Setting
Edmonton nights can drop past -30 °C, the City's design condition, so a heat pump needs a partner. Natural Resources Canada describes electric elements that run alongside the heat pump, and a furnace or boiler that takes over instead of running with it. A thermostat labelled Emergency or Aux heat uses only the backup. Use it as a temporary measure until the repair. If backup heat is running far more than before, or the house stays cold even with it, book service.
Mini Splits
The outdoor unit fails the same ways as a ducted system's. Indoors, check the remote first: fresh batteries and Heat mode. Then check the filter, and write down any blinking light or error code. Blocked drains and failed indoor fans or control boards need a technician. See mini splits in Edmonton and the Edmonton heat pump guide.
When to Call
Call if the checks fail, ice keeps returning, you hear grinding or banging, the unit cycles every few minutes or you smell burning. One Alberta service company lists a $125 plus GST diagnostic on weekdays and $185 plus GST on weekends and holidays.
The same repairs on an air conditioner in Edmonton, before GST: electrical part or thermostat $150 to $400, refrigerant leak find and recharge $200 to $500, compressor $1,000 to $2,500. More in heat pump repair cost in Edmonton.
If the unit is old and the quote is large, weigh it against a new one in heat pump repair or replace. A tune-up before winter is the best way to avoid a repeat.
Directory · 5 companies
Top-rated heat pump companies in Edmonton
Independently selected on Google rating, review volume and years in Edmonton. Every company here is rated 4.7 or higher. Tap one to open its Google listing, with phone number, hours and recent reviews.
-
View on Google
Friesen's Climate Control
Family owned and operated in Edmonton since 2007. Furnaces, air conditioning, heat pumps, water heaters and HRVs.
-
View on Google
Otto Heating & Cooling
Serving Edmonton since 2007. Furnaces, air conditioning, heat pumps and water heaters.
-
View on Google
Trust Home Comfort
Edmonton heating and cooling company on 27 Avenue NW. Furnaces, air conditioning, heat pumps and water heaters.
-
View on Google
Weiss-Johnson Heating, AC & Plumbing
Edmonton family business since 1977. Furnaces, air conditioning, heat pumps, boilers, water heaters, plumbing and HRVs.
-
View on Google
Acclaimed! Heating, Cooling & Furnace Cleaning
Family-owned Edmonton company since 1995. Furnaces, furnace cleaning, air conditioning, heat pumps and water heaters.
Frequently Asked Questions
Start with the thermostat mode, the breakers, the filter and snow around the outdoor unit. A silent outdoor unit after those checks points to a failed capacitor or contactor.
Usually defrost, or a thermostat on Auto or Cool. Air that stays cool means low refrigerant, a stuck reversing valve or a compressor fault.
Yes, during defrost. A unit that steams all the time, or ice that stays thick afterward, needs a technician.
A thin frost is normal. Thick ice suggests blocked airflow or a failed defrost control, refrigerant charge or reversing valve.
A thermostat setting that runs only the backup, either electric elements or the furnace. Use it temporarily.
Newer air-source models can run down to between -15 °C and -25 °C, according to Natural Resources Canada. Backup heat covers colder nights.
Often a clogged filter, a dirty coil, low refrigerant or a faulty sensor. Clean the filter and clear the unit, then call if it continues.
The diagnostic is $125 plus GST on weekdays at one Alberta service company. The same repairs on an Edmonton air conditioner run $150 to $400 for an electrical part, $200 to $500 for a leak find and recharge and $1,000 to $2,500 for a compressor.