HRV Not Working in Edmonton? What to Check First
Weak airflow, fogged windows, ice on the core or a noisy unit: find the symptom, try the free fixes and learn when to call someone.
In an Edmonton winter, most HRV complaints come down to three things: a dirty filter, an outdoor hood packed with snow or frost, or a humidity setting that suits last month's weather. All three are quick to check. A core that refreezes or an unbalanced unit needs a technician. This page deals with an HRV or ERV that is off, moving little air, icing up or leaving water on the glass. Disconnect the power before opening the unit.
Smell gas, or a carbon monoxide alarm sounding? Stop here. ATCO Gas says to leave the area immediately, go to a neighbour's house and call ATCO Gas at 1-800-511-3447, 911 or your local fire department right away, day or night. Indoors, do not use matches or lighters, do not smoke, do not use your phone, and do not turn light switches or other electrical switches or appliances on or off. If a carbon monoxide alarm sounds, get everyone outside and call 911. Natural Resources Canada adds that an HRV is not a substitute for fixing an appliance whose combustion by-products are escaping into the house.
Find Your Symptom
| What you notice | Likely cause | Who deals with it |
|---|---|---|
| Unit completely dead | Control off, cord unplugged, tripped breaker | You; a technician if the breaker trips again |
| Weak air at the grilles | Dirty filter, blocked hood, iced core, closed damper, loose duct | You |
| Fogged or wet windows | Humidity setting too high for the outdoor temperature | You: lower the setting |
| Ice inside the unit | Defrost falling behind, dirty filter, unbalanced airflow | You to thaw it; a technician if it comes back |
| Static, scratchy throat, dry air | Fan too fast or humidity set too low | You |
| Puddle or soaked duct insulation | Clogged drain or torn duct jacket | You, then a technician |
| Rattle, hum or vibration | Dusty fan blades, or the furnace blower | You, then a technician |
| Stuck on one speed, or cold drafts | Faulty control, or outlets in a poor spot | Technician |
HRV Not Running: Checks to Run First
- Control. Is the wall control on and in the right mode?
- Cord. Is the unit plugged in, with the cord in good shape?
- Breaker. A tripped breaker or blown fuse means calling a contractor. Natural Resources Canada warns against resetting either before the cause is known, since it can be a fire or shock hazard.
HRV Little or No Airflow
- Dig both outdoor hoods out of snow, frost and leaves, and check the ducts running to them.
- Wash or replace the filters.
- Hunt for a closed damper, a blocked register or something stuffed in a duct.
- Look at the core for frost.
- Find loose or leaking duct joints and tape them. The unit's door and internal gaskets should seal tightly.
Still weak? Time for a contractor.
HRV Condensation on Windows
Wet glass means the indoor air carries more moisture than the outdoor temperature can handle. Edmonton heating is sized for -30°C, and on a night that cold the setting has to be low. Work down this list:
- Lower the humidity setting. One utility guide suggests about 25% when it is -30°C outside and 35% at -18°C. The full table is in the Edmonton HRV guide.
- Reduce moisture at the source. Use the bathroom and kitchen fans and cut back on drying laundry indoors.
- Speed the HRV up.
- Run the trash bag test below.
If the glass stays wet, Natural Resources Canada says the unit's minimum continuous ventilation rate may be too low for the house. A contractor can correct that.
HRV Frozen: What to Do
Many HRVs begin an automatic defrost when incoming air falls below about -5°C, running longer as the temperature drops. If ice still builds, Natural Resources Canada recommends:
- Opening the door so the ice melts. Some cores lift out and can be thawed in a sink.
- Cleaning or replacing the filters.
- Checking the defrost mechanism or preheater, if there is one, against the manual.
- Calling a contractor if it recurs. The balance may need adjusting, with more exhaust flow or less supply flow.
HRV Drain and Water Problems
Pour two or three litres of warm water into the pan. If it backs up, poke the drain clear with thin wire. The tubing needs a trap. Drips or ice on a duct usually point to a hole in the insulation jacket. Foil duct tape fixes a small puncture. Wet or damaged insulation must be replaced and sealed again.
HRV Noise and Vibration
First, remove dust from the fan blades with a soft brush or vacuum, power disconnected. A unit that shares the furnace ducts can also pick up noise from the furnace blower at its higher heating speed. Grinding, rattling or a vibration that will not go away needs a technician.
HRV Air Too Dry
A dry throat and static shocks mean the HRV is pulling out more moisture than you want. Raise the humidity setting and run the unit on low or intermittently. Check that the exhaust is clear and the core is not iced. An ERV, which keeps some moisture in the house, is another option, though Natural Resources Canada says it costs more than the simpler remedies.
How Do I Know if My HRV Is Working? The Trash Bag Test
Tape a big trash bag to a coat hanger and hold it over the outdoor exhaust hood, timing how long it takes to fill. Then hold the full bag at the intake hood and time the emptying. If the two times are within a few seconds, the flows are roughly balanced. Natural Resources Canada calls it a rough check rather than a measurement.
When to Call a Technician
Call when the breaker trips, the core keeps icing, airflow stays weak after the steps above, humidity problems will not settle, or the unit is loud or stuck on one speed. A technician can measure and rebalance the airflow, test the defrost and inspect the wiring. HRV service is about $60 to $150 as an add-on, or $100 to $200 as its own visit: see HRV maintenance in Edmonton. If the unit is beyond repair, HRV installation cost in Edmonton covers a replacement. A new HRV needs a City HVAC permit, $124.80.
Directory · 2 companies
Edmonton companies that list HRV work
These top-rated Edmonton companies state HRV work on their own websites. Other listed companies may also do this work, so ask them. Tap one to open its Google listing, with phone number, hours and recent reviews.
-
View on Google
Friesen's Climate Control
Family owned and operated in Edmonton since 2007. Furnaces, air conditioning, heat pumps, water heaters and HRVs.
-
View on Google
Weiss-Johnson Heating, AC & Plumbing
Edmonton family business since 1977. Furnaces, air conditioning, heat pumps, boilers, water heaters, plumbing and HRVs.
Frequently Asked Questions
Confirm the control is on, the unit has power and the breaker is fine. Then wash the filters and clear the outdoor hoods. If it still will not run, or the breaker trips again, call a technician.
Indoor humidity is too high for the weather outside. Lower the setting, raise the fan speed and cut moisture sources. If it continues, the unit may not be ventilating the house enough.
The defrost cannot keep up, often because of dirty filters, a blocked hood or unbalanced airflow. Let the ice melt, clean the filters and call a contractor if it returns.
Most often a dirty filter, a snowed-in hood, a closed damper or an iced core. Clear those. If airflow stays weak, a duct may have come apart or the unit needs service.
The unit may be running too fast, or the humidity control is set too low. Raise the setting and run it on low or intermittently.
HRV service is about $60 to $150 as an add-on to a furnace or duct cleaning, and about $100 to $200 as its own visit. A new HRV installed is about $2,000 to $5,000 in Edmonton.